One running jacket lists RET 8; another states 20,000 g/m²/24 h. Both initially appear to concern breathability, yet you cannot compare eight directly with twenty thousand. They express different quantities, a favourable difference runs in different directions, and the test method is part of their interpretation. Numbers placed side by side provide meaningful information only once you understand exactly what they mean.

This article does not rank jackets. It unpacks a task in reading data: distinguishing resistance from a transmission value, handling incomplete product information, and keeping a laboratory result separate from comfort on your own run. The calculations are fictional illustrations, not measurements of specific products.

RET measures resistance, not the number of grams transmitted

RET describes resistance to evaporative water-vapour transfer. A lower value indicates less resistance. The public summary of ISO 11092:2026 identifies testing of thermal and water-vapour resistance under steady-state conditions; the usual RET unit is m²·Pa/W. The notation includes area, pressure and power associated with energy flow. This already shows that it does not describe a mass of water passing through in one day.

In everyday thinking, you may be accustomed to a higher product number suggesting greater capability. Here, that can easily lead you to read the result backwards. If two RET values were obtained with the same method on comparable samples, the lower means lower resistance. This does not automatically make the whole jacket better in every respect, nor does the difference imply a proportionally identical difference in your perceived comfort.

For illustration, imagine specification sheets showing RET 8 and RET 12. With appropriate measurement context, you can identify the direction of resistance from this pair. You cannot conclude that you will start sweating after half the time in one, or exactly one-third later in the other. Such a time-based or physiological conversion is not contained in the two figures. Define the data’s meaning more narrowly than your expectations.

MVTR is a mass-transfer-type value for a specified area and time

MVTR refers to the rate at which moisture passes through as water vapour. Clothing specification sheets often express it as grams per square metre per twenty-four hours. Rab’s manufacturer explanation separately discusses methods based on mass change and their different measurement approach from RET. Within the same, comparable transmission test, a higher figure indicates more water vapour passing through.

Read the unit in full. A value of 20,000 g/m²/24 h does not claim that the jacket you are wearing removes twenty kilograms of your own sweat every day under any conditions. You are looking at a test result expressed per unit area and time. Your garment’s shape, wearing conditions and surroundings are not simply a larger version of the laboratory sample.

In a practice example, one fabric receives 15,000 using method A and another 25,000 g/m²/24 h using method B. The higher number is not enough to establish a ranking: the relationship between the methods must first be clarified. If you do not know it, the accurate conclusion is that the data come from different tests. Do not replace missing methodological information with an attractive-sounding percentage advantage.

A runner examines the inner label and stitching of a technical top, also observing the fabric’s structure.Enlarge image
AI-generated editorial illustration of examining running clothing’s material and label; not a documentary photograph.

Why does an online conversion table not work for every jacket?

Calculating a relationship between two different physical quantities requires knowing the relationship and the necessary conditions. The digits of a RET result and an MVTR value alone do not provide all this information. Taking the reciprocal of one result or applying an arbitrary multiplier does not turn it into the other test’s result. A web table’s apparent precision does not resolve the missing information.

Distinguish an educational illustration from a correspondence between specific products. A manufacturer may show how it interprets its own test results. It does not follow that the same table applies to every other procedure and every brand’s figures. Be particularly wary of comparisons that rank numbers but omit the method, unit or sample condition.

If you encounter a claim that a particular RET corresponds exactly to a particular MVTR, ask under what conditions and using which measurements that correspondence was established. If the answer is absent, do not base a purchasing decision on it. A meaningful comparison instead means looking for additional data produced by the same procedure, or asking the manufacturer.

Conditions matter alongside the test’s name

Public descriptions of the ASTM family of water-vapour transmission methods identify different procedures and temperature and humidity conditions. Agreement between methods cannot be taken for granted. A standard’s designation is therefore an identification step that the phrase “industry test” cannot replace. Ask about the test data stated for the particular product; you do not need to learn every detail of fabric testing in general.

When collecting information, copy the complete designation, including any method variant and publication year. If the manufacturer states the test environment, record that too. Do not omit it because it makes the table longer. Precisely this additional detail can help establish whether two impressive numbers belong in the same comparison at all.

“No data” and “poor result” are different statements. A jacket for which you cannot find a measurement may still suit your purpose, but you cannot substantiate a numerical laboratory advantage for it. Conversely, detailed laboratory data do not prove that its size, hood or ease of use suits you. Documentation and suitability in wear are separate lines in the decision.

Air permeability and water-vapour transmission are different questions

The everyday word “breathable” can encompass several impressions. You may feel a draught through an open-weave fabric while a water-vapour test examines another phenomenon and produces another result. Wind passing through, water-vapour movement and ventilation through a zip should not be combined under one unexplained label. Ask which property the manufacturer means in the product description.

For example, a runner says a new top “does not breathe” because it felt warmer with the neck closed. That is a real experience, but not a measured RET in itself. Another runner makes the same jacket more comfortable by opening an underarm vent. The material’s stated laboratory property has not changed; the way the clothing system is used has changed. Preserve that distinction when describing feedback.

A useful description might be: “It felt stuffy uphill with the zip closed; on the flat return section it was more comfortable with the fastening open.” This contains a situation, a setting and an observation. “The membrane must be faulty” is a conclusion you cannot verify from that experience. Precise language is more valuable both in a customer-service enquiry and in equipment advice to friends.

The test cannot describe the whole jacket’s comfort for you

The ISO 11092:2026 summary explicitly distinguishes standardised testing from specific comfort situations. Take this seriously when expecting one material value to explain an entire workout. The jacket’s cut, layers, openings and how you wear it all contribute to your eventual experience. The laboratory result provides data for a bounded question, not for your whole running day.

During a fitting, examine usability separately. Can you reach the zip pull while wearing gloves? If you want ventilation, can you achieve it with your vest on? Does adjusting the hood remain comfortable when you look around? These questions do not replace material testing, but neither are they inferior: they provide a different kind of information about your own use of the garment.

If two jackets’ material data appear comparable but you cannot reach a necessary pocket in one, do not hide that behind the figures. A practical condition is allowed to be particularly important in your decision. Describe it as a reason arising from your use, however, rather than implying that a difference in operation proves a new laboratory result.

A hand in a thin glove tries a physical side button on a rain-speckled sports watch beside a jacket sleeve.Enlarge image
AI-generated editorial illustration; not a documentary photograph.

Three common specification-sheet situations, three different responses

In the first situation, both jackets have the same test and appropriately documented conditions. There is then a basis for comparing the direction of the stated material property. In the second, the values come from different methods: suspend direct ranking. In the third, there is only an adjective, such as “extremely breathable”. You can then ask for documentation behind the claim.

What do you see? What can be said? What remains open?
Two comparable RET values The lower indicates lower evaporative resistance. The complete garment and your own comfort.
RET on one sheet, MVTR on the other They state different quantities and use different approaches. There is no direct numerical ranking without further methodological context.
Same unit, missing procedure The unit alone does not establish comparability. The actual measurement method and conditions.
Only a promotional adjective The text makes a claim about use. The specific test supporting the claim.

Do not score uncertainty as zero in a comparison table, because zero can appear to be an interpretable result. Instead write “not stated”, “method unidentified” or “manufacturer clarification needed”. This preserves the distinction between a measurement difference and a simple lack of information. It also makes your own decision more transparent.

A good manufacturer enquiry offers more than ten decimal places

In a short enquiry, name the exact model and the data you do not understand. For example: “The product page gives a value in g/m²/24 h. Which test method produced it, and does it concern the material or the finished garment?” If your other candidate lists RET, you can mention that too, but do not request a universal conversion that the stated data do not support.

Keep the answer alongside the model and enquiry date. Do not automatically transfer one garment’s data to another across product families or generations. Information helps when you know exactly which material and version it concerns. The running jacket then ceases to be a numerical duel to win: laboratory data, documentation and your own fitting together provide a meaningful basis for deciding.

Sources and methodological scope

For the conceptual distinction, we used Rab’s manufacturer explanation of breathability testing; for the standard’s scope, the public summary of ISO 11092:2026; and for limitations of different water-vapour transmission procedures, the public method description for ASTM E96/E96M-22ae1. We do not claim that every product is tested using this ASTM edition, and did not analyse the full paid standards. The numerical examples and sample questions are our own editorial aids. Checked: 20 November 2026.

Helpful? Pass it on.